1.无影灯根据手术室尺寸和手术要求进行配置,采用多头型;调平板的位置在送风面之上,距离送风面不小于5cm。1. are configured according to the requirements of shadowless lamp size and operation room surgery, the head po*ition adjustment plate; on the air, the air surface distance of not less than 5cm.2.手术台长向沿手术室长轴布置,台面中心点与手术室地面中心相对应。The 2. station along the long axis to the surgical operation room layout, the center point and the center of the ground surface corresponding to the operation room.3.手术室计时采用兼有麻计时、手术计时和一般计时功能的计时器。手术室计时器有分、秒的清楚标识,并配置计时控制器,停电时能自动接通自备电池,icu净化,自备电池供电时间不低于10h。计时器设在患者不易看到的墙面上方,距地高度2m。
3. operation room timing,icu, both with anesthesia timing, surgery timing and general timekeeping function timer. Operation room timer has minutes and seconds of clear identification, and configuration timing controller,icu净化工程, power failure can automatically connect to own batteries, self battery,icu净化工程设计, power supply time is not less than 10h. The timer is located above the wall which is not easy to see by the patient. The height is 2m.
4.严格划分三区,即限制区、半限制区、非限制区。三区可设在同一楼层,有条件者可分设在相邻近的二个楼层。限制区应安排在内侧,包括手术间、洗手间和无菌敷料间。根据需要手术间可设无菌手术间与一般手术间。半限制区在中间,主要指敷料准备室、器械室、洗涤室、消毒室、麻醉苏醒室、麻醉准备室等,内镜室、感染手术间亦可放在此区内。非限制区在外侧,设更衣室、卫生间、值班室、标本间、污物处理间、休息室、小餐厅、麻醉及护士办公室、病人接收区、病人家属等候室等。
5.手术室必须设专用电梯。供接送病人及手术室工作人员使用。男女更衣室应设二个出入口,一端通换鞋室,另一端通手术区域。